Категории

EPP Series

Features

  • Universal AC input / Full range
  • Built-in active PFC function 
  • Class  I  or Class  II  installations 
  • No load power consumption <0.5W
  • High efficiency up to 94%
  • Protections: 
    • Short circuit / Overload / Over voltage /
    • Over temperature 
  • Built-in 12V/0.5A auxiliary output (12V/0.3A for EPP-100/150)
  • Built-in remote sense function (EPP-300/400)
  • LED indicator for power on 
  • 3 years warranty

Model No.

EPP-100

EPP-150

EPP-200

EPP-300

EPP-400

Rated

Power

Fan

100W (20CFM)

150W (20CFM)

200W (10CFM)

300W (20.5CFM)

400W (25CFM)

Convection

75W

100W

140W

200W

250W

AC input voltage range

90~264VAC

80~264VAC

90~264VAC

80~264VAC

DC adjustment range

-2%~+5% rated output voltage

±5% rated output voltage

Overload

protection

Range

105%~145%

115%~150%

105%~135%

115%~135%

Type

Hiccup mode, auto-recovery

Over voltage

protection

Range

115%~135% rated output voltage

110%~130%

115%~135%

110%~130%

Type

Shut down o/p voltage, re-power on to recover

Withstand voltage

I/P-O/P: 3kVAC, I/P-FG:2kVAC, O/P-FG: 0.5kVAC

I/P-O/P: 3kVAC, I/P-FG:2kVAC, O/P-FG: 1.5kVAC

Working temperature

-30~+70°C (refer to output derating curve)

Safety standards

UL60950-1, TUV EN60950-1 approved

EMC standards

EN55011 (EPP-300) / EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11

Connection

JST B3P / B4P-VH

JST B3P / B6P-VH

JST B5P-VH / Screw terminal

Dimension (LxWxH)(mm)

101.6x 50.8x 29

127x 76.2x 35