Категории

RPS Series

Features

  • Universal AC input / Full range
  • Medical safety approved (2xMOPP)
  • Suitable for BF application with appropriate system consideration (RPS/D/T-160)
  • Built-in active PFC function (RPS/D/T-160)
  • Protections: 
    • Short circuit / Overload / Over voltage /  
    • Over temperature (RPS/D/T-160)
  • /RZOHDNDJHFXUUHQWȝ$ ȝ$IRU536'7 
  • With power good and fail signal output (RPS/D/T-160)
  • Built-in remote sense function (RPS-160 5~15V)
  • No load power consumption <0.75W (RPS-75&RPS/D/T-160 G model) 
  • 6WDQGE\9#$ 536'7*PRGHO
  • LED indicator for power on
  • 3 years warranty

Model No.

RPS/D/T-75

RPSƒ-160

RPDƒ- 160

RPTƒ-160

Rated Power

Fan

100W (23.5CFM)

160W (20.5CFM)

150W (20.5CFM)

Convection

75W

110W

100W

AC input voltage range

90~264VAC

DC adjustment range

CH1: -5%~+10% rated output voltage

±10%

0~+10%

Overload protection

140%~180% hiccup mode, auto-recovery

105%~135% hiccup mode, auto-recovery

Over voltage protection

CH1: 110%~135% shut down o/p voltage, re-power on to recover

Withstand voltage

I/P-O/P: 4kVAC, I/P-FG:2kVAC, O/P-FG: 1.5kVAC

Working temperature

-20~+70°C (refer to output derating curve)

Safety standards

ANSI/AAMI ES60601-1, TUV EN60601-1 approved

EMC standards

EN55022, EN55011 class B, EN61000-3-2,-3; EN60601-1-2

Connection

JST B3P / B8P-VH

Dimension (LxWxH)(mm)

127x 76.2x 31

127x 76.2x 34.6