Категории

QP/TP Series

Features

  • Universal AC input / Full range
  • Protections:  
    • Short circuit / Overload / 
    • Over voltage / Over temperature
  • Over temperature protection  
  • (200~320W built-in, option for 100W and 150W)
  • Built-in active PFC function
  • Cooling by free air convection (75W / 100W)
  • Forced air cooling by built-in DC fan  (150W / 200W / 320W)
  • 100% full load burn-in test
  • 3 years warranty

Model No .

TP - 75

TP - 100

QP - 100

TP - 150

QP - 150

QP - 200

QP - 320

AC input voltage range

90~264VAC; 127~370VDC

AC inrush current (max .)

Cold start,

20A at 230VAC

Cold start,

40A at 230VAC

Cold start,

50A at 230VAC

Cold start,

45A at 230VAC

DC adjustment range

CH1:

-5%~+10% rated output voltage

CH1: -5%~+10% rated output voltage (CH1&2 for QP-100/150-3x,

QP-100/150-D/F)

CH1&2: - 5%~+10% rated output voltage

Overload

protection

Range

105%~150%

Type

Hiccup mode, auto - recovery

Constant current

limiting,

auto - recovery

Fold back current 

limiting,  

auto-recovery

Over voltage protection

CH1: 115%~135%

115%~135% for CH1 or CH1&2

Withstand voltage

I/P - O/P: 3kVAC, I/P - FG: 2kVAC, O/P - FG:0 . 5kVAC, 1 minute

Working temperature

-10~+60°C (refer to output derating curve) 

- 10~+70°C

Setup, rise, hold up time

800ms, 60ms, 36ms

at full load and

230VAC

800ms, 60ms, 24ms at full load and

230VAC(TP-100/150);

800ms, 50ms, 24ms at full load

and 230VAC (QP - 100/150)

800ms, 50ms, 24ms

at full load and

230VAC

800ms, 50ms, 16ms

at full load and

230VAC

Safety standards

UL60950 - 1, TUV EN60950 - 1 approved

EMC standards

EN55022 class B, EN61000 - 3 - 2,3, EN61000 - 4 - 2,3,4,5,6,8,11

Connection

8P/7 . 62mm pitch

terminal block

9P/7 . 62mm pitch terminal block with cover

9P/9 . 5mm pitch terminal block with cover

Dimension (LxWxH)(mm)

179x 99x 33

199x 99x 50

215x 115x 50

Case No .

920A

916A

916B

912B

912 I