Категории

SP Series

Features

  • Universal AC input / Full range 
  • Built-in active PFC function 
  • Protections:  
    • Short circuit / Overload / Over voltage / 
    • Over temperature
  • Forced air cooling by built-in DC fan
  • Built-in fan speed control (SP-320)
  • Built-in remote sense function and ON/OFF control 
  • (SP-480/750 & PSP-600)
  • Current sharing up to 2400W (3+1) (PSP-600)
  • With DC OK signal output (PSP-600)
  • With PG/PF signal output (SP-750)
  • 100% full load burn-in test
  • 3 years warranty

Model No .

SP - 320

SP - 480

PSP - 600

SP - 750

AC input voltage range

88~264 VAC

85~264VAC

88~264VAC

90~264VAC

AC inrush current (max .)

Cold start, 40A at 230VAC

Cold Start, 45A at 230VAC

DC adjustment range

±10% rated output voltage

Overload

protection

Range

105%~135%

105%~145%

105%~135%

105%~125%

Type

Hiccup mode, auto - recovery

Constant current limiting, auto - recovery

Constant current limiting, auto - recovery

Constant current limiting,hiccup after 3sec.

Over voltage protection

115%~145%

115%~140%

Withstand voltage

I/P - O/P: 3kVAC, I/P - FG: 1 . 5kVAC, O/P - FG: 0 . 5kVAC(short for SP - 480), 1 minute

Working temperature

- 20~+65°C

- 20~+60°C

Safety standards

UL60950 - 1, TUV EN60950 - 1 approved; GB4943 approved also for SP - 320 (expect for 3 . 3V/ 5PNC/ 36V)

EMC standards

EN55022 class B, EN61000-4-2,3,4,5,6,8,11, EN61000-3-2,3, EN61000-6-2(SP-480/750), GB9254 (SP-320 only)

Connection

9P / 9 . 5mm pitch terminal

block with cover

9P / 11mm pitch terminal

block with cover

7+8P / 9 . 5mm pitch

terminal block with cover

5P / 10mm pitch terminal

block with cover for input;

copper pillars for output

Dimension (LxWxH)(mm)

215x115x50

278x127x43

170x120x93

278x127x63 . 5

Case No .

912G

929A

910A

919A

Packing

12pcs / 14 . 0kg

6pcs / 11 . 3kg

8pcs / 15 . 5kg

6pcs / 18 . 4kg