Категории

S Series

Features

  • Dual in line package (DIP24)
  • 2:1 wide input range
  • I/O isolation: 1000VDC (8W), 1500VDC (12W)
  • Protections: Short circuit / Overload
  • Five-sided shield metal case
  • Cooling by free air convection
  • Built-in remote ON/OFF control (SCW/DCW12)
  • Modified models available: output 2.5V/3.3V (SCW/DCW12)
  • 2 years warranty

Model No.

SCW08

DCW08

SCW12

DCW12

Vin range

A: 9~18V, B: 18~36V, C: 36~72V

Vo accuracy (Typ.)

±2%

Line regulation (max.)

±0 . 5%

Load regulation (max.)

“±0.5%@20%-100% load

Short circuit protection

Continuous, hiccup mode, auto-recovery

Overload protection

110%~250%, auto-recovery

110%~180%, auto-recovery

I/O isolation voltage (min.)

1000VDC

1500VDC

I/O isolation resistance (min.)

100MΩ@500VDC

Working temperature

- 40~+71°C (refer to output derating curve)

EMC standards

EN55022 class B, EN61000-4-2,3,4,5,6,8,

FCC part15 class B without external components

EN55022 class A, EN61000-4-2,3,4,5,6,8,

FCC part15 class A without external components

Dimension (LxWxH)

1.25"x 0.8"x 0.48" (31.8x 20.3x12.2mm)